Tychkov V. Methods for improving primary transducers quality in the systems of automatic process water control.

Українська версія

Thesis for the degree of Candidate of Sciences (CSc)

State registration number

0417U004026

Applicant for

Specialization

  • 05.13.05 - Комп'ютерні системи та компоненти

05-10-2017

Specialized Academic Board

К 73.052.04

Cherkasy State Technological University

Essay

The dissertation is devoted to the improvement of the quality of the measuring control of technological water in the computerized system of automatic control by using the flow-injection method of analysis and development and improvement of the primary transformers, elements for the devices of these systems. Models of ionometric primary converters have been developed by using as a basis of a conductive mixture of powders from non-magnetic and ferromagnetic metals with solid binding dielectrics. The elements for computerized flow-injection ionometric SAC devices and the method of measuring halogen-containing substances, which make it possible to simplify the procedure for controlling the quality of technological water, have been developed.

Files